O Extremely high pulse duty
O Self-healing
O Internal series connection
O Very low dissipation factor
O Negative capacitance change
versus temperature
O AEC-Q200 qualified
O According to RoHS 2011/65/EU
Capacitance range:
100 pF to 4.7 F (E12-values on request)
Rated voltages:
400 VDC, 630 VDC, 1000 VDC, 1250 VDC,
1600 VDC, 2000 VDC, 4000 VDC,
6000 VDC
Capacitance tolerances:
±20%, ±10%, ±5% (other tolerances are
available subject to special enquiry)
Operating temperature range:
–55° C to +105° C
Climatic test category:
55/100/56 in accordance with IEC
Test voltage: 2 sec
Dielectric absorption: 0.05%
Insulation resistance at +20° C:
C T 0.1 F: 1 x 105 MΩ
C 0.1 F: 30000 sec (MΩ x F)
Measuring voltage: 100 V/1 min.
Voltage derating:
A voltage derating factor of 1.35 % per K
must be applied from +85° C for DC
voltages and from +75° C for AC
voltages
Reliability:
Operational life 300000 hours
Failure rate 1 fit (0.5 x Ur
and 40° C)