• Industry-leading ultra-low power consumption
– 5-Hz version: 0.54 µA with 1.8 V
– 20-Hz versions: 1.6 µA with 3 V
• 1.65-V to 5.5-V operating VCC range
• Magnetic threshold options (maximum BOP):
– 3.9 mT, highest sensitivity
– 4.8 mT, high sensitivity
– 9.5 mT, medium sensitivity
– 63 mT, lowest sensitivity
• Omnipolar and unipolar options
• 20-Hz and 5-Hz sampling rate options
• Open-drain and push-pull output options
• SOT-23, X2SON and TO-92 package options
• –40°C to +85°C operating temperature range