n Dual 50A or Single 100A Digitally Adjustable Outputs with
Digital Interface for Control, Compensation and Monitoring
Wide Input Voltage: 4.5V to 16V
Output Voltage Range: 0.5V to 1.8V
~90% Full Load Efficiency from 12VIN to 1VOUT at 100A
±0.5% Maximum DC Output Error Over Temperature
±3% Current Readback Accuracy (25°C to 125°C)
Integrated Input Current Sense Amplifier
400kHz PMBus-Compliant I2C Serial Interface
Supports Telemetry Polling Rates Up to 125Hz
Integrated 16-Bit ∆Σ ADC
Constant Frequency Current Mode Control
Parallel and Current Share Multiple Modules
15mm × 22mm × 7.87mm BGA Package
Readable Data:
Input and Output Voltages, Currents, and Temperatures
Running Peak Values, Uptime, Faults and Warnings
Internal EEPROM and Fault Logging with ECC
Writable Data and Configurable Parameters:
Output Voltage, Voltage Sequencing and Margining
Digital Soft-Start/Stop Ramp
Optimize Analog Loop Compensation
OV/UV/OT, UVLO, Frequency and Phasing