FKP1R026807B00KSSD

Category:

Download Details PDF

Notice:

In stock will ship in 2 days. Real-time inventory pls confirm with us.

INQUIRY ONLINE




    SPECIFICATION

    O Extremely high pulse duty
    O Self-healing
    O Internal series connection
    O Very low dissipation factor
    O Negative capacitance change
    versus temperature
    O AEC-Q200 qualified
    O According to RoHS 2011/65/EU

    Capacitance range:
    100 pF to 4.7 F (E12-values on request)
    Rated voltages:
    400 VDC, 630 VDC, 1000 VDC, 1250 VDC,
    1600 VDC, 2000 VDC, 4000 VDC,
    6000 VDC
    Capacitance tolerances:
    ±20%, ±10%, ±5% (other tolerances are
    available subject to special enquiry)
    Operating temperature range:
    –55° C to +105° C
    Climatic test category:
    55/100/56 in accordance with IEC
    Test voltage: 2 sec

    Dielectric absorption: 0.05%
    Insulation resistance at +20° C:
    C T 0.1 F:  1 x 105 MΩ
    C  0.1 F:  30000 sec (MΩ x F)
    Measuring voltage: 100 V/1 min.
    Voltage derating:
    A voltage derating factor of 1.35 % per K
    must be applied from +85° C for DC
    voltages and from +75° C for AC
    voltages
    Reliability:
    Operational life  300000 hours
    Failure rate  1 fit (0.5 x Ur
    and 40° C)