BTA41-800BRG

Available in power packages, the BTA40, BTA41, and BTB41 are suitable for general
purpose AC switching.
When used with the properly dimensioned heatsink, the BTA40, BTA41 and BTB41
can enable AC switching systems up to 9 kW. Refer to STMicroelectronics
application note AN533 for thermal management of Triacs.
The BTA40, and BTA41 provides an insulated tab (rated at 2500 V rms). They are
recognized by UL. Representative samples of these components have been
evaluated by UL and meet applicable UL requirements for the UL 1557 standard (file
Ref. 81734).


Download Details PDF

Notice:

In stock will ship in 2 days. Real-time inventory pls confirm with us.

INQUIRY ONLINE




    SPECIFICATION

    Manufacturer STMicroelectronics
    Series
    Packaging Tube
    Part Status Active
    Triac Type Standard
    Voltage – Off State 800 V
    Current – On State (It (RMS)) (Max) 40 A
    Voltage – Gate Trigger (Vgt) (Max) 1.3 V
    Current – Non Rep. Surge 50, 60Hz (Itsm) 400A, 420A
    Current – Gate Trigger (Igt) (Max) 50 mA
    Current – Hold (Ih) (Max) 80 mA
    Configuration Single
    Operating Temperature -40°C ~ 125°C (TJ)
    Mounting Type Through Hole
    Package / Case TOP-3 Insulated
    Supplier Device Package TOP3
    Base Product Number BTA41